NEC NDA-30130 Answering Machine User Manual


 
Page 2 NDA-30130 Revision 1
INSTALLATION & SET-UP Voicemail Disconnect Installation & Operation Manual
Voicemail Disconnect
Set-Up
Application
Configuration
Voicemail Disconnect is supported internally by the APM, and must be configured
in the APM environment. The Software Installation procedure configures the
application using default values and creates the databases needed.
Database Support
Voicemail Disconnect requires two APM databases: the Phone line database and
the Tenant Number Database. Empty databases are created during initial software
installation, but specific records must be added before Voicemail Disconnect is
enabled.
Note:
If Second Party Alert Ver1.7 or higher has been previously installed, then these
databases have already been created.
Phone Line Database
The Phone Line database consists of a Master Database file component and an
Application Database file component.
Master Database File filename - ’phone_m’
.
The phone_m master database structure and example entries are shown in the table
below.
Field Definitions
- Phone Line 1 field is the primary extension number (five-digits max.). The
number that is displayed with the caller’s name when this phone is used to
place the call.
- Phone Line 2 - 6 fields are the secondary, or virtual, lines that are associated
with the primary extension that was entered in the first field. These virtual
lines must be assigned to this primary line through the NEAX Maintenance
Administration Terminal (see NEAX2400 System Manuals).
Field Name
Type Size Min.
Value
Max.
Value
Example
Entry
Phone Line 1 N 5 0 99999 4290
Phone Line 2 N 5 0 99999 4291
Phone Line 3 N 5 0 99999 4292
Phone Line 4 N 5 0 99999 4293
Phone Line 5 N 5 0 99999 4294
Phone Line 6 N 5 0 99999 4295