PBUS Accessories
Several accessories (keypads, proximity readers, remote receivers) can
be connected to the AE-1000’s three PBUS input/output ports. A typical
application for a remote keypad would be to control a second door or
gate.
Linear’s PBUS devices compatible with the AE-1000 are:
AM-RRR Remote Radio Receiver
AM-RPR Radio Proximity Receiver
AM-KP Exterior Keypad
AM-KPI Interior Keypad
AM-CRI Card Reader Interface
1. Mount and install the accessory as described in its installation
instructions.
2. Route 6-conductor cable from the AE-1000 to the accessory.
For wire runs up to 300 feet use 24 AWG Belden Type 9931 or
equivalent.
For wire runs up to 600 feet use 20 AWG Weico Type 9405 or
equivalent.
3. Set the DEVICE ADDRESS rotary switch in the accessory to
a unique address number. When programming the system, the
device address number will identify each PBUS accessory to the
AE-1000.
4. Connect the 6-conductor cable to the accessory and the AE-1000.
Wiegand Accessories
The two AE-1000 Wiegand inputs (WIEGAND A & B) can connect to
a large variety of 26, 30, and 31-bit Wiegand output accessories. The
Wiegand format is a common standard for access control equipment.
A typical application would be to add swipe card or proximity readers to
the system.
NOTE: Depending on the Wiegand accessory used, the LED1,
LED2, and HOLD connections may not be required.
LED1 output is switched to ground during non-access time.
LED2 output is switched to ground for one second during access
time.
1. Mount and install the Wiegand accessory as described in its
installation instructions.
2. Route a cable from the AE-1000 to the accessory.
For wire runs up to 300 feet use 24 AWG Belden Type 9931 or
equivalent.
For wire runs up to 500 feet use 20 AWG Weico Type 9405 or
equivalent.
3. Connect the cable to the accessory and the AE-1000 as shown in
the fi gure.
REMOTE
PBUS
DEVICE
PCLK
DVAL
DAT0
DAT1
GND
PWR
GND
DAT1
DAT0
DVAL
PCLK
PWR
PBUS
TERMINALS
SET THE REMOTE
DEVICE ADDRESS
SWITCH TO A UNIQUE
DEVICE ADDRESS
NOTE: UP TO SIX PBUS
DEVICES MAY BE CONNECTED
TO THE THREE SETS OF AM-1000
PBUS TERMINALS
REMOTE
WIEGAND
DEVICE
LED2
HOLD
LED1
DAT1
DAT0
GND
DAT0
DAT1
LED1
HOLD
LED2
GND
WIEGAND
TERMINALS
PWR
PWR
NOTE: THE LED1, LED2, AND HOLD
CONNECTIONS MAY NOT BE REQUIRED
DEPENDING ON THE WIEGAND DEVICE USED