Kenwood TK-3180 Two-Way Radio User Manual


 
TK-3180
24
Item Condition
Measurement Adjustment
Specifications/Remarks
Test-
equipment
Unit Terminal PartsUnit Method
ADJUSTMENT
• Wide 4k 3) Adj item : [s SQL] SSG Panel ANT Panel
Selector
After input signal After adjusting SQL, check
Adjust : [✳✳✳] knob from SSG, press [B] SQL open/close.
SSG output :
–118dBm (0.28µV)
AF VTVM
Universal
key. That numeric SSG –118dBm : Open
(MOD : 1kHz/±2.4kHz)
Oscilloscope
connector
will be stored in SSG OFF : Close
memory. [nC SQL] MOD 1kHz/±1.5kHz
4) Adj item : [sL SQL] [sC SQL] MOD 1kHz/±2.4kHz
[sC SQL][sH SQL] [wC SQL] MOD 1kHz/±3.0kHz
Adjust : [✳✳✳]
• Wide 5k 5) Adj item : [w SQL]
Adjust : [✳✳✳]
SSG output :
–118dBm (0.28µV)
(MOD : 1kHz/±3.0kHz)
6) Adj item : [wL SQL]
[wC SQL][wH SQL]
Adjust : [✳✳✳]
6. Low RSSI 1) Adj item : [n LRSSI] After input signal
adjust Adjust : [✳✳✳] from SSG, press [B]
• Narrow SSG output :
–118dBm (0.28µV)
key. That numeric
(MOD : 1kHz/±1.5kHz) will be stored in
memory.
2) Adj item : [nL LRSSI]
[nC LRSSI][nH LRSSI]
Adjust : [✳✳✳]
• Wide 4k 3) Adj item : [s LRSSI]
Adjust : [✳✳✳]
SSG output :
–118dBm (0.28µV)
(MOD : 1kHz/±2.4kHz)
4) Adj item : [sL LRSSI]
[sC LRSSI][sH LRSSI]
Adjust : [✳✳✳]
• Wide 5k 5) Adj item : [w LRSSI]
Adjust : [✳✳✳]
SSG output :
–118dBm (0.28µV)
(MOD : 1kHz/±3.0kHz)
6) Adj item : [wL LRSSI]
[wC LRSSI][wH LRSSI]
Adjust : [✳✳✳]
7. Squelch 1) Adj item : [n SQLT] After input signal After adjusting SQL, check
(Tight) Adjust : [✳✳✳] from SSG, press [B] SQL open/close.
adjust SSG output :
–113dBm (0.5µV)
key. That numeric SSG –113dBm : Open
• Narrow (MOD : 1kHz/±1.5kHz) will be stored in SSG OFF : Close
memory.
[nC SQLT] MOD 1kHz/±1.5kHz
2) Adj item : [nL SQLT]
[sC SQLT] MOD 1kHz/±2.4kHz
[nC SQLT][nH SQLT]
[wC SQLT] MOD 1kHz/±3.0kHz
Adjust : [✳✳✳]
• Wide 4k 3) Adj item : [s SQLT]
Adjust : [✳✳✳]
SSG output :
–113dBm (0.5µV)
(MOD : 1kHz/±2.4kHz)
4) Adj item : [sL SQLT]
[sC SQLT][sH SQLT]
Adjust : [✳✳✳]