Kenwood PKT-23K Amplified Phone User Manual


 
12
CHANNEL SETUP MODE
This transceiver allows you to reprogram each of the channels
with different frequencies and QT (Quiet Talk)/ DQT (Digital
Quiet Talk) settings. The table below lists the default channel
settings.
Channel
Number
Table
Number
Frequency QT/DQT Setting
1 2 464.5500
MHz
67.0 Hz
2 8 467.9250
MHz
67.0 Hz
3 9 461.0375
MHz
67.0 Hz
4 10 461.0625
MHz
67.0 Hz
OPERATING FREQUENCY AND QT/ DQT SETTING
To change the operating frequency of a channel:
1 With the transceiver power OFF, press and hold the PTT
switch and Up key while turning the transceiver power ON.
Continue to hold the Power switch, PTT switch, and Up
key until the LED indicator lights yellow and the transceiver
announces “Self”.
2 Release the Power switch, PTT switch and Up key.
The transceiver announces “Channel Number”.
3 Press the Up/Down key to select your desired channel, then
press the PTT switch to confi rm the selected channel.
Upon releasing the PTT switch, a beep will sound and the
transceiver announces “Table Zero”.
4 Press the Up/Down key to increment/ decrement the Table
number, to select the new channel frequency.
Press and hold the Up/Down key to continuously increment/
decrement the number.
Table numbers and their corresponding operating frequencies
are provided in the tables on pages 13 and 14.
A voice announcement will inform you of the selected Table number.