Icom IC-M88 Two-Way Radio User Manual


 
21
8
SET MODE
D Battery voltage indicator bt
This function contains display or non-display settings of the
voltage of the connected battery pack when the power is ON.
The voltage of the connected battery pack is displayed for 2 sec.
after power is turned ON.
D Scrambler code cd (Available for I/S version only)
There are 32 codes (1 to 32) available for programming. In
order to understand each other, all transceivers in your group
must have the same scramble code.
Battery voltage OFF
(default)
Battery voltage ON
PUSH
Scrambler code 1 (default) Scrambler code 32
PUSH
Indication Switch
Beep tone function
Function
Weather alert function
Priority scan function
Scan resume timer
Auto scan function
Dual/Tri-watch function
Monitor switch action
Automatic backlighting
LCD contrast selection
Auto power save function
Self check function
OFF / ON* / US
OFF* / ON
OFF* / ON
OFF* / ON
OFF* / ON
Dual* / Tri
Push* / Hold
OFF / 1 / 2 / 3*
1 / 2 / 3* / 4
OFF / ON*
OFF* / ON
OFF* / ON
"bP"
"AL"
"Pr"
"St"
"AS"
"dt"
"Sq"
"bL"
"LC"
"PS"
"SC"
"bt"
Battery voltage indicator
Scrambler code** "cd" 1* / 2 / / 32
SET MODE LIST
* default setting
** Available for I/S version only