HTC PDA PHONE II Telephone User Manual


 
HTC confidential
© 2001, HTC Corporation. All rights reserved. TOTAL 77 CONT.ON. 39 PAGE NO. 38
-4. Current measurement .
Measured value should be within the range:-3.125 ~ +3.125 V.
5- CC and DC status Check
Both Pin should be in LOW , otherwise it is judged as defective.
Following table is the criteria for Voltage and current status:
ITEM Description Measurement status
1
Battery VOLTAGE Voltage should be 2.5 V
A
bove. If the voltage is under 2.5, it
means that the battery is over discharged and defective.
2*
Battery Current Current should be between –3.125 ~ + 3.125 mAH
Voltage > 2.5 V
Voltage should Exceed 2.5 V
1.Current mesurement
It should have the value within
+ 3.125~ -3.125 mAh
2. If value incorrect, need to Click “Calibrate Offset
“ button first for double confirmation.
The value will be calibrated automatically. (it may
takes about 15~ 20 seconds)