Furuno FS-1562-15 Telephone User Manual


 
-3.1-
Chapter 3 CHANGING SYSTEM
SETTING
3.1 SYSTEM SETUP
1. While pressing and holding down the [RCL] key, turn on the power. Release the [RCL] key
when the “MEMO” appears on the display.
MEMO
System code
Setting value
2. Turn the FREQ/CH control to select a desired code number.
3. Press the [RCL] key, enter desired setting by a numeral key, then press the [ENT] key.
4. To change setting for another code, repeat steps 2 and 3.
5. Turn off the power, then turn it on.
3.2 CUSTOMIZING BY OPERATOR
The operator can customize the parameters for scan, sweep and squelch function. The table below
shows the system codes and their function, setting range and factory setting.
Code Function, Setting
9918 Key response
Turns on/off key beep which sounds when wrong key is operated.
0: OFF
1: ON (Factory Setting)
9919 Noise blanker activation
Turns on/off noise blanker.
0: OFF
1: ON (Factory Setting)
9920 AGC activation
Turns on/off AGC. ON/OFF automatically activates or deactivates AGC
depending on class of emission.
0: OFF
1: ON
2: MODE (Factory Setting)