4-3
4.2 Connecting of NBDP Terminal Unit
OP05-96 (IB-581)/OP05-100 (IB-583)
To use this equipment for the telex, the NBDP terminal unit is required.
Name: NBDP terminal set, Type: OP05-96, Code No.: 000-056-949
Name Type Code No. Qty Remarks
Terminal unit IB-581-02 000-043-350 1 set w/installation materials
DSP Board OP05-97 005-951-820 1 05P0751A
Name: NBDP terminal set, Type: OP05-100, Code No.: 000-056-956
Name Type Code No. Qty Remarks
Terminal unit IB-583 000-043-435 1 w/installation materials
DSP Board OP05-97 005-951-820 1 set 05P0751A
Inserting the DSP Board
1. Open the cover of the transceiver unit.
2. Remove the shield cover from the T-CPU Board (05P0732).
3. Attach the DSC Board (supplied) on J5 and J6 of the T-CPU Board.
Attach DSP
Board here.
T-CPU Board
J1
Location of DSP Board
4. Remount the shield cover.
5. Close the cover of the transceiver unit.
Mounting location for terminal unit
• Leave sufficient space around the unit for operation and maintenance.
• The temperature and humidity of the mounting location should be stable and moderate.
• Keep the unit away from the high power radiotelephone and it’s feeder wire so that RFI
(Radio Frequency Interference) is minimum.
Mounting of IB-581
Refer to the outline drawing at the back of this manual.
1. Fix the hanger by using five tapping screws (supplied with option kit).