Avaya 1600 IP Phone User Manual


 
Administering Options for the 1600 Series IP Telephones
Issue 1 June 2007 65
PHNLDLENGTH 10 Length of national telephone number. The number of
digits in the longest possible national telephone
number by the algorithm that dials calls from the
incoming Call Log or from Web pages. Range: 1 or 2
digits, from “3” to “10.” Range: 1 or 2 ASCII numeric
characters, from “5” to “15.”
PHNOL 9 Outside line access code. The character(s) dialed,
including # and *, if any, to access public network local
trunks by the algorithm that dials calls from the
incoming Call Log or from Web pages. Range: 0-2
dialable characters, including " " (Null).
PHY1STAT 1 Ethernet line interface setting (1=auto-negotiate,
2=10Mbps half-duplex, 3=10Mbps full-duplex,
4=100Mbps half-duplex, 5=100Mbps full-duplex, and
6=1000Mbps full-duplex if supported by the hardware).
PHY2PRIO 0 Layer 2 priority value for frames received on or
forwarded to the secondary Ethernet interface. Set this
parameter only when VLAN separation is "1"
(enabled). Values are from 0-7 and correspond to the
drop-down menu selection.
PHY2STAT 1 Secondary Ethernet interface setting
(0=Secondary Ethernet interface off/disabled,
1=auto-negotiate, 2=10Mbps half-duplex, 3=10Mbps
full-duplex, 4=100Mbps half-duplex, 5=100Mbps
full-duplex), and 6=1000Mbps full-duplex if supported
by the hardware).
PHY2VLAN 0 VLAN identifier used by frames received on or
forwarded to the secondary Ethernet interface. Set this
parameter only when VLAN separation is "1"
(enabled). Value is 1-4 ASCII numeric digits from “0” to
“4094.” Null is not a valid value, nor can the value
contain spaces.
PROCPSWD " " (Null) Text string containing the local (dialpad) procedure
password (Null or 1-7 ASCII digits). If set, password
must be entered immediately after Mute is pressed and
before entry of a procedure command (for example,
VIEW). Intended to facilitate restricted access to local
procedures even when command sequences are
known. Password is viewable, not hidden.
PROCSTAT 0 Local (dialpad) Administrative procedures status
(0=Local procedures enabled, 1=all Administrative
Options are disabled).
REREGISTER 20 Registration timer in minutes. Controls an H.323
protocol timer that should only be changed under very
special circumstances by someone who fully
understands the system operation impact. Value is
1-120.
Table 7: 1600 Series IP Telephone Customizable System Parameters (continued)
Parameter Name Default Value Description and Value Range
4 of 6