Aiphone JK-DVF-AC Intercom System User Manual


 
7
EnglishFrançais
Nederlands
Thissectionexplainsthesettingsofeachfunction,includingthemastercodeformanagement,theusercodeforunlocking,the
buzzer and the LEDs.
About the setting mode:
Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings for
the desired function. After settings have been made, enter the following setting codes to continue the setting operation.
Press
to exit the setting mode.
Setting items Allowable setting range Default value
Setting code
Setting the code length
Change the length of the master code and the user code.
)Theybothmustbethesamelength.
4, 5, or 6 digits 4 digits
Setting the master code
Enteramastercodeusingbetween4and6digits(alphaornumeric)to
switch to the setting mode.
)Thenumberofdigitsinthecodecanbesetbysettingthecodelength.
1
Validkeys:0-9,A,B
1234
Setting the code for user group 1
Settheunlockingcodeforusergroup1.
)Thenumberofdigitsinthecodecanbesetbysettingthecodelength.
Numberofcodes:60
Validkeys:0-9,A,B
-
-
Setting the code for user group 2
Settheunlockingcodeforusergroup2.
)Thenumberofdigitsinthecodecanbesetbysettingthecodelength.
Numberofcodes:40
Validkeys:0-9,A,B
-
-
Setting the key illumination time
Setthelengthoftimethatthekeyswillbelitupaftertheyarepressed.
Illuminationtime:10to99
seconds, or continually lit
10 Sec.
Setting the relay 1 output time
Set the output time of relay 1.
Outputtime:1to99
seconds, or latched
3 Sec.
Setting the relay 2 output time
Set the output time of relay 2.
Outputtime:1to99
seconds, or latched
3 Sec.
Reset Settings
Return all the settings to their default values.
- -
External output setting
The alarm or security system connected to the terminal of relay 2 will be
activatedwhenthe"Lockout"*ortheforcedentry*iscarriedout.
*"Lockout":RefertoVIIIbelow.*Forcedentry:Thisfunctionislinkedwith
thedooropen/closesensor(N.C.)whichisconnectedtoPB2andC,and
carriedoutwhenopeningthedoorwithoutactivatingthisunit.(Forexample,
entryinanimpropermanner,manualunlock,etc.)
)Ifthereisawaytoopenthedoorwithoutactivatingthisunit,suchas
manualunlock,donotmaketheexternaloutputsettingfortheforcedentry.
· OFF
·DuringLockout
· During forced entry output
·
Duringlockoutandforced
entry output
OFF
Lockout
If several incorrect access codes are attempted, the code input function is
disabled for a programmed period of time.
·When"Lockout"isactivated,theLED(Orange)indicatorandthekeypad
blink,andthebuzzersoundsfor3seconds.Thisisjustasoundtoinform
you that the function has been activated. It is not a warning sound. If you
want a warning to be sounded, please use the external output function to
activate a commercially-available alarm device.
· Theunlockfunctionwillworkwhentherequesttoexit/entrybuttonis
pushed,evenwhilethe"Lockout"functionisoperating.
ON/OFF
Invalidnumberoftimes:
10 to 99 times
Invalidtime:
10 to 99 seconds
OFF
Auto-relock (Anti-tailgate)
Afterthedoorhasbeenlinkedtothedooropen/closesensor(N/C),and
unlocked,itwillrelockitselfonesecondafterbeingclosed,thuspreventing
the entry of an unauthorized third party.
1
ON/OFF OFF
Timer-linked unlocking setting
Thesystemcanbesettounlockthedoorbypressingthe keywithin
thesettimeandlinkingittotheexternaltimer(N/O).Theoperationsforthe
LEDsandthebuzzerafterunlockingarethesameasthoseusedtoperform
usercodeunlocking.Whenthedoorislinkedtothetimer,unlockingcanbe
performedusingtheusercodeandtherequesttoexit/entrybutton.When
latch output is performed for the relay settings, the relay turns ON/OFF
every time the
keyispressed.
Linkedrelay:relay1
relay 2
relay 1 and 2
0keyillumination:ON/OFF
Linkedrelay:relay1
0keyillumination:OFF
Operation tone settings
SetthetoneheardwhenthekeypadisbeingusedtoON/OFF.
ON/OFF ON
• Thesettingcanbesavedevenwhenthepowerisoff.
• Thesystemcannotbeswitchedtothesettingmodewhiletherelayisunlocked.
• Whenthesettingmodehasbeenactivatedandnooperationsareperformedforapproximately120seconds,thesystem
willexitthesettingmode.(Ifakeyispressedduringthattime,thetimerwillstartover.)
• Neithertherequesttoexit/entrybuttonnorthetimer-linkedunlocking
keycanbeoperated,andunlockingusingthe
user code cannot be performed while the setting mode is activated.
•
Thevolume(thechecktone,operationtone,etc.)fromthedoorstationmaybecomeloweraccordingtothemountingstatus.
1
:Whentheauto-relockisused,therequesttoexit/entrybuttonforrelay2cannotbeused.Theoutputofrelay2is
onlypossiblewhenusercodeunlockingisperformed.
FUNCTIONS/SETTING UP FOR ACCESS CONTROL
JK-DVF-AC_ENG.indd 7 2009/10/05 21:18:42