5
EnglishFrançais
Nederlands
Wiring distance
Power supply Diameter Distance
A - 0.65mm(22AWG) 50m(165')
- 1.0mm(18AWG) 100m(330')
B 12 - 18V AC or DC
or less
0.65 - 1.0 mm
(22-18AWG)
100m(330')
18 - 24V AC or DC 0.65 - 1.0 mm
(22-18AWG)
300m(980')
C - 0.65 - 1.0 mm
(22-18AWG)
300m(980')
D - The connection distance will depend on
thespecicationsoftheelectricdoorstrike,
relaysorelectromagneticdoorlocktobe
connected. To determine the operating
range,pleaserefertothespecicationsof
each terminal.
N/C contact
Power supply
User group1 relay 1 User group2 relay 2
Request to
exit/entry
button 1
Request to
exit/entry
button 2
N/C contact
N/O contact N/O contact
Power supply
Between 12 and 24V AC
Between 12 and 24V DC
Request to exit/entry button, Timer
Minimum overload : 100mV DC, 0.1mA or above
Contact capacity : 3V DC, 0.1A or above
Relay
24V DC, 3A (resistive load) 1A (inductive load)
24V AC, 3A (resistive load) 1A (inductive load)
Minimum overload : 5V DC, 100mA or above
V V
A1 A2
PB1 PB2 C T NO1 C1 NC1 NO2 C2 NC2
TimerCommon
JK-1MDJK-1MED
A
B
2
2
2
2
2
2
2
2
CD
A1
A2
A1
A2
L
L
Master station
Video door station
Video
door
station
Access control keypad
Access
control
keypad
Power supply
Request to exit/entry button
Timer
Relay
Relay
Automatic gate
Electromagnetic
doorlock
Electricdoorstrike
or
Request to exit/entry button
or
or
WIRING AND CONNECTIONS
Outline of connections and wiring distance
Terminal names
(Terminals for Video door station)
(Terminals for Access control keypad)
JK-DVF-AC_ENG.indd 5 2009/10/05 21:18:37