Aiphone 834168 C P0811JZ Intercom System User Manual


 
25
Connections
C
SP
SP
S
SE
NO
COM
PAGING
CONTACT
IN
CONTACT
OUT
150m (490')
D1
D4
CAT5e/6
150m (490')
D1
D8
CAT5e/6
150m (490')
C1
C30
CAT5e/6
2C
2C
P
NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50')
φ0.65-1.2mm
(22-16 AWG)
15m (50')
φ0.65-1.2mm
(22-16 AWG)
15m (50')
*1: Output speci cations
Output method N/O dry closure contact
Voltage between
terminals
24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC):
100mV, 0.1mA
*2: Input speci cations
Input method N/O or N/C dry closure contact (start
signal only detection method)
Detection con rmation
time
100 ms or more
Contact resistance During N/O dry closure: Less than 700 Ω
During N/C dry closure: At least 4 k Ω
Terminal short current Less than 10 mA
Voltage between
terminals
Less than 5 V DC (when open between
terminals)
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
For connecting other manufacture’s products, refer to the instruction manuals for those products.
The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
Central control unit
(IS-CCU)
External speaker
(more than 8Ω 3W)
Add-on control unit
(IS-SCU)
Room sub control unit
(IS-RCU)
or
or
Contact input
*2
(Sensor, etc.)
Contact output
*1
(Electric door strike,
strobe light, etc.)
(Select one port.)
(Select one port.)
(Select one port.)
(non-shielded)
(non-shielded)
(non-shielded)
NP: Non-polarized
P: Polarized