Add-on control unit
(
IS-SCU
)
Part names
NOTE:
The illustration of the unit may differ from the actual one.
Speci cations
Add-on control unit (IS-SCU)
Power source 48V DC (supplied from the power supply unit)
Current consumption Max. 1.2A
Ambient temperature 0 - 40°C (+32°F - +104°F)
Talk channels Video
channels
Local system: 2 talk & 2 video channels,
1 chime
Master station(s) Max. 8
Video door station(s)
Max. 8Audio door station(s)
Room sub station(s)
Video output
NTSC
BNC (Video channel 1,2)
Mounting Rack-mount (19-inch, 2U rack) or wall mount
Material Steel plate
Color Black
POWER switch
Turns the power ON (
) or OFF ( ).
VIDEO OUTPUT port 1 and port 2
Central control unit (IS-CCU) ports
* No connection allowed.
CONTACT OUTPUT terminals
PA (Paging) OUTPUT terminals
MASTER STATION ports
VIDEO/AUDIO DOOR/SUB STATION ports
POWER LED (green)
Lights up when the power is ON.
POWER terminals
ID setting switch
(P.13)
STATUS LED (green)
Blinks when this unit is initialized or an error
*
1
occurs.
The LED will light up when this unit returns to
the normal state.
*
1
: Communication error in a unit connected
to this unit, or between this unit and a unit
connected to it, etc.