TOA Electronics CP-63 Intercom System User Manual


 
Appendix. Instructions for building the CP-63 in the EXES-5000
1. The CPU-55/56 differ from the CP-62/63 in dial operation.
Function
Continuous Calling Tone
One-touch Response
8 Selectable Make Output
CPU-55 CPU-56
X: 1 ~ 9, Y: 0~ 7
CP-62
CP-63
X: 1 ~ 9, Y: 1 ~ 8, 0 (Clear)
X: 1 ~ 9, Y: 1 ~ 8, 0 (Clear)
2. Set the DIP switch SW-E-5 (change-over of Privacy and Continuous Calling Tone) to OFF (Privacy). Set the other DIP
switches according to the necessity.
3. The "Automatic Access to Paging" function is not available from the EXES-5000 system. You, therefore, need not
program the "Automatic Access to Paging" function (Function Code No. 54) referred to in Function Code Table for
Station NO No. 200 Programming.
4. Module units necessary for the tie-line system.
Note.
1. To ensure the complete speech functions (perfect simultaneous speech, calls and responses made by means of a
handset, etc.) that the stations of EXES-6000 system can have, 2-wire stations as well as the LM-62 is necessary.
2. The exchange using the frame FR-510 or FR-520 allows for no tie-line connection to the other exchange. The tie-line
connections are only possible among the exchanges using the frame FR-510A, FR-520A, FR-510B, FR-520B, FR-610
or FR-620.
3. For the following module units, you may use whichever you proper: SGD-52A and SG-62 (the SG-62 is necessary
when the LM-62 is used.)
PIU-52A and PI-62
TI-52 and TI-62
4. When the CP-63, OC-62 and DL-62 are used in the tie-line system, the speech link of the calling exchange is in the full
duplex mode, while voice switches cause the speech link of the called exchange to be in the automatic alternative
speech mode.
Function
All functions
Conversation
Conference
Exchange "A"
Exchange "B"
Possible or
impossible
Possible
Impossible
Possible
Impossible
Possible
Impossible
Possible
Reason
2 voice switch passes
1 voice switch passes
3 voice switch passes
1 voice switch passes
Necessary module units
• It is impossible to use both the
CPU-56 and the CP-63 in the
same system.
DLU-52
or
• DL-62, OC-62
• It is impossible to use both the
CPU-56 and the CP-63 in the
same system.
• CL-62, DL-62, OC-62
— 57 —