SpectraLink 72-1084-02 IP Phone User Manual


 
SpectraLink Corporation Setup and Administration—NetLink e340/i640 Wireless Telephone
Mitel Networks ICP and 5220 IP Phone emulation
PN: 72-1084-02-B.doc Page 39
Message Description Action
No SVP IP The Wireless Telephone is
configured for “static IP” (as opposed
to “use DHCP”) and no valid NetLink
SVP Server address has been
entered.
Enter a valid NetLink SVP server
IP Address in the configuration
setting or change to “use DHCP.”
No SVP Response The NetLink SVP Server is not
responding to requests from the
Wireless Telephone.
This may be caused by bad radio
reception or a problem with the
NetLink SVP Server. The Wireless
Telephone will keep trying to fix the
problem for 20 seconds, and the
message may clear by itself. If it
does not, the Wireless Telephone
will restart. Report this problem to
the system administrator if it keeps
happening.
No SVP Server Wireless Telephone can’t locate SVP
Server.
IP Address configuration of
NetLink SVP Server is wrong or
missing.
SVP Server is not working. Check error status screen on
NetLink SVP Server.
No LAN connection at the SVP
Server
Verify NetLink SVP Server
connection to LAN.
No Net Access Cannot authenticate / associate with
AP
Verify the AP configuration.
This indicates any of the following:
No radio link
Verify that the AP is turned on.
No ESSID – Autolearn not
supported (or)
incorrect ESSID
Verify the ESSID of the wireless
LAN and enter or Autolearn it
again if required.
No Net Found
Out of range
Try getting closer to an AP. Check
to see if other Wireless
Telephones are working within the
same range of an AP. If so, check
the ESSID of this Wireless
Telephone.
Incorrect WEP settings
Verify that all the WEP settings in
the Wireless Telephone match
those in the APs.
No Reg Domain Regulatory Domain not set. Configure the Regulatory Domain
of the Wireless Telephone
Not Installed! A required software component is
missing.
Check that all required software
files are on the TFTP server, if
over-the-air downloading is being
used. If the error repeats, contact