Samsung DCS-816 Telephone User Manual


 
SAMSUNG Installation
DCS-816 March 1999
6-4
6.4 Door Phone and Door Lock Release (Figure 6-3)
The DCS DPIM module is required to install a door phone or a door lock release. The DPIM has a
door phone interface and a door lock release circuit, which can be connected to any DLI port of
DCS-816. The system requires MDF connection for DPIM modules and modular jack connection
for a door phone or a door lock release. DPIM connections can be done through the champ
connector on the base board. See Figure 2-3 and refer to section 2.5 (MDF Cabling).
Use one pair twisted wires, connect each DPIM module to the DLI port of your choice via the
champ connector on the base board and connect a door phone or a door lock release to the
DPIM.
CONNECTING A DOOR PHONE AND LOCK RELEASE
25 PAIR CABLE WITH FEMALE CONNECTOR TO THE BASE CHAMP CONNECTOR
FIGURE 6-3
CHAMP CONNECTION
PIN COLOUR CIRCUITS / FUNCTIONS
39/14 BK-BR/ BR/BK T/R, 1
st
DLI port on base
40/15 BK-S/ S-BK T/R, 2
nd
DLI port on base
41/16 Y-BL/ BL-Y T/R, 3
rd
DLI port on base
42/17 Y-O/ O-Y T/R, 4
th
DLI port on base
43/18 Y-GR/ GR-Y T/R, 5
th
DLI port on base
44/19 Y-BR/ BR-Y T/R, 6
th
DLI port on base
45/20 Y-S/ S-Y T/R, 7
th
DLI port on base
46/21 VL-BL/BL-VL T/R, 8
th
DLI port on base
47/22 VL-O/ O-VL T/R, 9
th
DLI port on base
48/23 VL-GR/ GR-VL T/R, 10
th
DLI port on base
49/24 VL-BR/ BR-VL T/R, 11
th
DLI port on base
50/25 VL-S/ S-VL T/R, 12
th
DLI port on base
² CONNECT A DPIM TO ANY DLI PORT AFTER
CONNECTING A DOOR PHONE TO THE DPIM
² NO EQUIPMENT CAN BE INSTALLED
OUTDOORS
² DOOR LOCK RELEASE RATE : 24VDC, 1A MAX
LOCK DOOR BOX LINE
£Ð£«
£Ð£-
£Ì£±
£Ì£²
DOOR PHONE
RED
BLACK
GREEN
YELLOW
TWO PAIR
M
O
D
U
L
A
R
C
A
B
L
E
WHITE
BLUE
T
H
R
E
E
P
A
I
R
MODULAR CABLE
TO CUSTOMER-PROVIDED
DOOR LOCK RELEASE
1
6
4
5
3
2
3 4
Technical Manuals Online! - http://www.tech-man.com