Polycom RMX 2000 Telephone User Manual


 
Polycom RMX 2000 Hardware Guide
1-17
Replacing a Functional MPM Module
The MPM module is Hot Swappable and the power on the RMX can stay
ON. For more information see - Use the following procedure to replace a
faulty MPM Module types F or H:
1 Unscrew the captive screws on the front panel of the RMX that secure
the MPM Module.
2 Use the metal ejector levers to pull the MPM Module out of its slot in
the Backplane.
3 Carefully slide the MPM Module out through the front panel.
4 Slide in the replacement MPM Module.
5 Push the MPM Module firmly into the Backplane, making sure it is
properly seated in its slot.
6 Ensure that the metal ejector levers are fully retracted into their
housings.
7 Tighten the captive screws on the front panel of the RMX that secure
the MPM Module.
8 Restart the RMX2000.