1-4
Overview
Table 1-1. Call Stacker Connectivity Chart.
SYSTEM CONNECTIVITY
FORWARD
DISCONNECT
STATION GROUPING
PARTNER PLUS
Yes (Release 2 or
later)
Standard Hunt Group
PARTNER II Yes Standard Hunt Group
Spirit 308/616,
1224/2448
No — —
Merlin 206/410/820 No — —
Merlin II Yes (Release 3) Yes (see note 1) GCD (Group Call Distribution)
Merlin Plus No — —
Merlin 1030/3070 No — —
Legend Yes Yes (see note 2) Calling Group, Circular
System 25 Yes Standard Station Hunting, Circular
Definity Yes Yes (see note 3) UCD (Uniform Call Distribution)
System 85 Yes Yes (see note 4) UCD (Uniform Call Distribution)
Dimension No — —
Horizon Yes Standard Hunt Group, Circular
NOTE:
1. In order for the Merlin II to send a forward disconnect, set the station option for AA/VMS. The 012
station module must be “F” version or greater.
2. Make the Calling Group a “Generic VMI” type.
3. In order for the Definity to send a forward disconnect, Adjunct Supervision needs to be optioned “Yes” at
the station level.
4. In order for the System 85 to send a forward disconnect, the Class of Service needs to change to
“Origination Restriction.”