Lucent Technologies LULCST Telephone User Manual


 
Installation
2-3
2.Set the option switch on the Call Stacker (see Figure 3-1 on page 3-2) for the
desired system configuration (refer to Table 2-1).
NOTE: When the switch
#7 is “OFF”, there
will be no delay in time
from when the paging
system zone is
accessed until the time
when the message is
sent. When the switch
#7 in “ON”, there will
be a 2 second delay
from when the paging
system/zone is
accessed until the time
when the message is
sent. The delay is
installed in order for a
Confirmation/
Pre-announcement
tone (if available or
optioned) to be played
over the system before
the message is sent.
3.Connect the Call Stacker to the paging system (see Figure 2-4):
Connect the Call Stacker's Page Output to the attendant override (attendant
access control leads) or incoming alarm signal from the paging system.
NOTE: PBX and KTS
stations must have the
ability to send a
forward disconnect to
the Call Stacker's
Station inputs.
Connect one or more of the Call Stacker's Input Station channels to PBX/KTS
analog station inputs on the telephone system through FCC/DOC approved
modular jacks.Connect the Call Stacker's Page Output channel to the paging
system as shown in Figures 2-4 and 2-5 through an FCC/DOC approved modular
jack. The control contact signal is used to secure and release the paging system
controller (see figure 2-3).
Table 2-1. Option Switch Setting.
SET
SWITCH
# 1 TO
SET
SWITCH
# 2 TO
SET
SWITCH
# 3 TO
SET
SWITCH
# 4 TO
SET
SWITCH
# 5 TO
SET
SWITCH
# 6 TO
SET
SWITCH
# 7 TO
Number of DTMF Digits in Zone Code
0 ONON—————
2 OFFON—————
3 ONOFF—————
4 OFFOFF—————
Voice Prompts
None ONON———
English only OFF ON
Spanish only ON OFF
English/Spanish OFF OFF
Length of Recording Cut Off (when user hangs up during recording)
None ———ONON
0.25 sec———OFFON
0.50 sec———ONOFF
0.75 sec———OFFOFF
Confirmation or Pre-Announcement Tone
2 Second Delay——————
SEE NOTE