Linksys SPA962 Telephone User Manual


 
Linksys SPA9x2 Phone Administration Guide 64
Advanced Scripting for Cadences, Call Progress Tones, and Ring Tones
Setting Regional Parameters
A ToneScript is a mini-script that specifies the frequency, level and cadence parameters of a call
progress tone. It can contain up to 127 characters. The syntax follows:
•FreqScript;Z
1[;Z2]. The section Zi is similar to the Si section in a CadScript except that
each on/off segment is followed by a frequency components parameter: Zi = Di(oni,1/
offi,1/fi,1[,oni,2/offi,2/fi,2 [,oni,3/offi,3/fi,3 [,oni,4/offi,4/fi,4 [,oni,5/offi,5/fi,5 [,oni,6/
offi,6/fi,6]]]]])
where fi,j = n1[+n2]+n3[+n4[+n5[+n6]]]]] and 1 < nk < 6 indicates which of the
frequency components given in the FreqScript are used in that segment; if more than
one frequency component is used in a segment, the components are summed together.
Example 1: Normal Ring
60(2/4)
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60 s
Number of Segments = 1
Segment 1: On=2s, Off=4s
Total Ring Length = 60s
Example 2: Distinctive Ring
(short,short,short,long)
60(.2/.2,.2/.2,.2/.2,1/4)
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60s
Number of Segments = 4
Segment 1: On=0.2s, Off=0.2s
Segment 2: On=0.2s, Off=0.2s
Segment 3: On=0.2s, Off=0.2s
Segment 4: On=1.0s, Off=4.0s
Total Ring Length=60s