Hubbell Electric Heater Company TI984 Telephone User Manual


 
PAGE 12 of 14
MODEL TI984 TELEPHONE INTERFACE 42004-071F
f:\standard ioms - current release\42004 instr. manuals\42004-071f.doc
05/03
Programming Table
*Function SELECT INCOMING CALL - SELECTIVE ACCESS METHOD
KEY SEQUENCE # 3 2 P P M M A X Y
DESCRIPTION If selected, incoming calls receive a coded beep to indicate if the designated party
line is in use. After hearing the coded beeps, the caller can select either voice
access method or ring access method. Refer to Selective Access Method on page 8.
PP = number of seconds of voice page (00 to 99)
MM = number of seconds after the page that the call must be answered (00 to 99);
if call is not answered, it is terminated.
A = auto-connect option: 1 to enable or 0 to disable
X = access code digit for caller to select voice access method (0 to 9)
Y = access code digit for caller to select ring access method (0 to 9, must be
different than X)
Example: To set a 15-second voice page, a 25-second period after the end of the
page before the call reverts to the auto-connect option, to enable the auto-connect
option, to set the code to enter voice access method at 2, and to set the code to enter
page access method at 5, enter the following code: # 3 2 1 5 2 5 1 2 5
Function SET NUMBER OF INCOMING RINGS
KEY SEQUENCE # 4 N
DESCRIPTION Sets the number of rings that must elapse before the TI984 acknowledges an
incoming call. This function provides time for an operator to intercept incoming
calls. Example: To set the incoming ring delay at 4 rings, enter the following code:
# 4 4. The TI984 then answers the call after the fifth ring.
Function SET HANG UP DELAY
KEY SEQUENCE # 9 N N
DESCRIPTION
NN is the number of seconds (00 to 99) that elapse after all Page/Party
®
stations on
the designated party line are on-hook, and the outside call is disconnected. As
explained above, this time should not be set to zero in case users want to page
during the conversation. The average time for this delay should be around 7
seconds. To program a 7-second hang-up delay, enter the following code: # 9 0 7
Function SET DAY/NIGHT SWITCH (INTERNAL/EXTERNAL)
KEY SEQUENCE # 8 X
DESCRIPTION
Sets the method of switching between day and night modes. If the front panel
Day/Night switch is to be used, select INTERNAL. If the selection is made using a
remote switch, select EXTERNAL. Example:
To select internal Day/Night switching, enter: # 8 1.
To select external Day/Night switching, enter: # 8 0
*Choose only one of these functions for each mode: one for Day mode and one for Night mode.