Honeywell 2020 Cordless Telephone User Manual


 
4 - 6
Interfunction Delay
An interfunction delay of up to 495 milliseconds may be placed between the
transmission of each segment of the message string. Scan the Interfunction
Delay barcode below, then scan the number of milliseconds and the SAVE bar-
code using the Programming Chart inside the back cover of this manual.
To remove this delay, scan the Interfunction Delay barcode, then set the num-
ber of steps to 0. Scan the SAVE barcode using the Programming Chart inside
the back cover of this manual.
Intermessage Delay
An intermessage delay of up to 495 milliseconds may be placed between each
scan transmission. Scan the Intermessage Delay barcode below, then scan
the number of milliseconds and the SAVE barcode using the Programming
Chart inside the back cover of this manual.
To remove this delay, scan the Intermessage Delay barcode, then set the num-
ber of steps to 0. Scan the SAVE barcode using the Programming Chart inside
the back cover of this manual.
Interfunction Delays
Prefix Scanned Data Suffix
1 2345STX HT CR LF
Interfunction Delay
2nd Scan Transmission1st Scan Transmission
Intermessage Delay
Intermessage Delay