FIRMWARE VERSION 1.0.3.1 HT70X USER MANUAL Page 15 of 52
HARDWARE SPECIFICATION
The table below lists the Hardware and Technical specification of HT70X.
TABLE 5: HT70X HARDWARE AND TECHNICAL SPECIFICATIONS
HT701
HT702
HT704
Telephone
Interfaces
1 RJ11 FXS port
2 RJ11 FXS ports
4 RJ11 FXS ports
Network
Interface
1 RJ45 10/100 Mb Base-TX, Full Duplex
1 RJ45 10/100 Mb Base-TX,
Full Duplex port with
connectivity LEDs
LED Indicators
POWER, INTERNET,
LINK/ACTIVITY, PHONE
POWER, INTERNET,
LINK/ACTIVITY,
PHONE1, PHONE2
POWER, PHONE1, PHONE2,
PHONE3, PHONE4
Factory Reset
Button
Yes
Universal
Switching
Power Adaptor
Input: 100240 VAC/50-60 Hz 0.18A Max
Output: 12VDC, 0.5A, UL certified
Input: 100240 VAC/50-60 Hz
0.18A Max
Output: 12VDC, 1A, UL certified
Environmental
Operational: 32
o
104
o
F or 0
o
40
o
C
Storage: 14
o
140
o
F or -10
o
60
o
Humidity: 1090% Non-condensing
Dimensions
(H x W x D)
26 x 65 x 86mm
28 x 115 x 75mm
28 x 115 x 75mm
Short Haul Loop
5REN, Up to 1Km on 24 AWG
wire
3REN: Up to 1Km on 24 AWG line
Polarity
Reversal / Wink
Yes
EMC
FCC part15 Class B, EN55022, EN55024, CISPR22, and CISPR24
Safety
EN60950-1 & UL60950-1 (UL only for PSU)
Compliance