Grandstream Networks GXW-400X FXS Telephone Accessories User Manual


 
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM GXW400X - HT50X DOCUMENT NUMBER
©
2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE. PAGE 9 OF 25
3.2 Interoperability Issues
This section lists the known interoperability issues between BroadWorks and partner
release(s). For more information on issues related to the particular software release, see
the partner release notes (generally, this should only be for GA partner releases).
Issue Tracking
Number
Issue Title and Description Partner Releases
BroadWorks Release 14
1.0.0.39
1025 - 61
Broadworks to DUT, Do Not Disturb (DND) ring splash
DUT does not play a ring splash. DUT driver does not support ring
splash.
X
1025 -119 DUT to BroadWorks via Primary Application Server, DUT
Currently Served by Secondary Application Server
DUT does not always contact the primary server first for INVITE. It
relies on the OPTIONS message from BroadWorks to failback.
When DUT is registered on secondary server and the primary
server becomes available and sends an OPTIONS request, DUT
will send INVITE to the primary server.
X