6.2 Subscriber Level Configuration Parameters
This section identifies the device-specific parameters, including registration and
authentication. These settings must be unique across devices in order to be matched with
the settings for a BroadWorks subscriber.
Provisioning a subscriber to register with BroadWorks allows calls to terminate to the
subscriber’s line. Registration requires that a unique address of record (AoR) is
provisioned on BroadWorks and the phone; provisioning an AoR on BroadWorks consists
of setting the line/port parameter to a unique value within the Application Server cluster.
Grandstream GXW-4004 / GXW-4008 / HT-502 supports four SIP accounts (lines), eight
SIP accounts, and two SIP accounts respectively. The follow example shows how to
configure subscriber elements for an account.
Step Command Purpose
Subscriber Configuration Items
Step 1
Set Register User ID for each
line.
Example:
SIP User_ID = "2405551111" ;
The register user ID must
correspond with the line/port
setting on BroadWorks.
Step 2
Enable SIP Authentication for
each line.
Example:
Authenticate ID =
"1111@as.mycompany.com" ;
Authenticate Password =
"welcome" ;
If the Authentication service is
configured on BroadWorks, these
parameters must be configured to
match the BroadWorks settings.
Step 3
Configure display name for each
line.
Example:
Name = “Claire Smith” ;
For each line, configure the name
to be displayed on the device.
Step 4
Select SIP Profile for each line.
Example:
Profile ID = Profile 1
Set SIP Profile or each line.