252
IrDA Environment Setup Commands
Wait Time Setup (/L)
Function
This function sets up the Wait time for communication.
Starting method
int argc = Number of parameter arguments
char* argv[] = { "fl", "/L={, wait time for connection establishment, wait time for data
reception/transmission,,,,}" }
DoFlink(argc, argv)
If the parameters for the L option do not have to be entered, enter only comma separators. If this is
the case, default values will be automatically used.
Wait time for connection establishment
Specify 0 to 3600 (second)
If 0 is specified, the process takes until connection establishment.
The default value is 1800 seconds.
Wait time for data reception/transmission
Specify 0 to 3600 (second)
If 0 is specified, the process takes until the end (normal end or abnormal end).
The default value is 300 seconds.
Parameter setup examples
argc = 2
argv[] = { “fl” , “/L={,20,,,,,}” }
Following the parameter setting shown above as example, the environment setting can be done
according to the details listed in the table below.
Parameter Process value Remark
Wait time for connection establishment 20 sec.
Wait time for data transmission/reception 300 sec. Default