Bogen UTI312 Pager User Manual


 
15
Auto Select Zone Group
Auto Select provides paging to a programmed zone group when the unit is accessed without having to enter any
DTMF k
eys.This feature is useful when voice paging is always to all zones, but only certain zones are to receive tone
trigger signals. No user-controlled zone selection is permitted for paging when this feature is enabled.Auto Select
paging does not interfere with Override, Night Ring,Tone Trigger
1, and Tone Trigger 2 zone groups. For information
on programming or disabling Auto Select, refer to the
System Programming section.
To page to the Auto Select zone group:
1. Dial the paging access number for your telephone system.
2. Listen for pre-announce tone (if enabled).
3. Make the page and hang up when finished.
Override Zone Group & Tone
By default, the Override zone group is programmed to include all zones.The Override feature gives the caller the
ability to trigger an Override announcement in a programmed zone group.When Override is activated, a quad beep
pre-announce tone will precede the announcement.The tone can be enabled or disabled (the default is enabled).
This feature has the highest priority.See System Programming to program the Override zone group or to disable the
tone.
Night Ring Zone Group & Tone
By default, the Night Ring zone group is programmed to include all zones.The Night Ring feature gives the caller
the ability to trigger a Night Ring tone in a programmed zone group.The Night Ring tone may be programmed to
be a simulated ring or chime tone (the default is simulated ring).This tone is produced when either of the Night
Ring inputs are activated.This feature is above Background Music and below Override,Tone Triggers 1 and 2, and
Paging in the priority structure. See System Programming to program the Night Ring zone group and to choose the
tone.
Tone Trigger 1 & 2 Zone Groups & Tones
By default, the Tone Trigger zone groups are programmed to include all zones.The Tone Trigger feature gives the
caller the ability to trigger a particular tone in a programmed zone group.This tone is activated when the Tone 1
or Tone 2 and C terminals are shorted together.A 3-second tone burst is the default setting for both Tone Triggers.
These tones have the second highest priority after Override with Tone Trigger
1 having a higher priority than Tone
Trigger 2.
Several tone options are available:
2 - 7 second tone burst - This is a tone burst that, once a momentary closure is detected at the tone trigger input,
will sound f
or the set duration one time.The UTI312 will not r
espond to the tone trigger input while the tone is
in pr
ogress. If the closure is still present at the tone trigger input upon completion of the tone, then the UTI3
12
will not sound the tone again until the closure is removed and applied again.
Tone follow contact -This is a tone burst that will sound continuously as long as a contact closure is present at
the tone trigger input.
Double chime tone - This is a chime tone that will sound twice when a closure is detected at the tone trigger
input. The UTI3
12 will not respond to the tone trigger input while the tone is in progress. If the closure is still
present at the tone trigger input upon completion of the tone, the UTI312 will not sound the tone again until the
closure is removed and applied again.
Chime tone follow contact - This is a chime tone that will sound continuously as long as a contact closure is
pr
esent at the tone trigger input.
Slow whoop follow contact - This is a slow whoop tone that will sound continuously as long as a contact closure
is present at the tone trigger input. Momentary contact will produce one cycle of slow whoop.
Note:
The volume le
vel of these tones and all of the tones (with the exception of the Night Ring tone) ar
e contr
olled b
y the
Tone Level Control.