Bogen UTI312 Pager User Manual


 
12
ZX3 Module Connections
ZX3 Module Paging Output Connections
There are three zone paging outputs on the ZX3 module. The paging
outputs ar
e intended to connect to self-amplified speakers, but are also
compatible with amplifier inputs as well. The Tip (T) and Ring (R)
connections are transformer-isolated audio outputs for driving up to 150
self-amplified speaker inputs.
ZX3 AUX Contacts
Each zone on the ZX3 module has a C-form contact rated at 1A @ 30V
DC and 0.5A @ 125V AC.They change state when the corresponding
zone becomes active.The ZX3 AUX contacts are not programmable.
ZX3 Power Supply Output
A 24V DC, 1A regulated power supply,built into the UTI312,can be used
to suppl
y power to self-amplified speakers through a 2-pin plug-in
connector on the ZX3 module.The + and - terminals provide 24V DC
for powering the self-amplified speakers.The UTI3
12 can supply a total
of 1A @ 24V DC thr
ough all of these connectors.