Bogen LUMDMU Telephone User Manual


 
5
Set the MDMU options on the DIP switch. Refer to
the table below.
NOTE: Switches 1, 2, and 3
sets the number of messages in
a single queue sequence. The
timing between those
messages is set by switches 4,
5, and 6. Switch 7 sets the
total possible number of
messages for the unit. Switch
8 is always in the ON position.
REM
OPTION
BATTERY
SWITCH
OFF ON
Figure 6 Set MDMU Options on DIP Switch
Table 1. DIP Switch Setting Definitions
MAX. No. of
MESSAGES IN
SEQUENCE:
SET
SWITCH
# 1 TO
SET
SWITCH
# 2 TO
SET
SWITCH
# 3 TO
SET
SWITCH
# 4 TO
SET
SWITCH
# 5 TO
SET
SWITCH
# 6 TO
SET
SWITCH
# 7 TO
1
ON ON ON
2
OFF
ON
ON
3
ON
OFF
ON
4
OFF
OFF
ON
5
ON ON
OFF
6
OFF
ON
OFF
7
ON
OFF
OFF
8
OFF
OFF
OFF
DEFAULT DELAY BETWEEN MESSAGES:
0:05
ON
ON
ON
0:10
OFF
ON ON
0:30
ON
OFF
ON
1:00
OFF
OFF
ON
5:00
ON
ON
OFF
15:00
OFF
ON
OFF
30:00
OFF
OFF
OFF
NUMBER OF MESSAGES AVAILABLE:
1 TO 9
ON
01 TO 99
OFF
5