- 10 -
Room-to-room communication
English
1. Press the CALL button once.
2. The "All Call" function is activated to link all of the inside
stations.
3. If another person presses the TALK button, handsfree
communication is possible.
4. Press and release the TALK button to end.
.
Do not press the TALK button during communication in
step 3. It will end the communication.
NOTES: 1. Room-to-room communication ends
automatically after approx. 1 minute.
To have another room-to-room conversation,
repeat from step 1.
2. If a call is received from an entrance station
during room-to-room communication, a chime
tone sounds only at the master station where
communication is taking place. Quickly end
room-to-room communication, then the system
switches to the calling entrance station.
7-7
1
3
2
JB-2MED
TALK
CALL
MONITOR
REC
PLAY
SET
JB-2MED
TALK
CALL
MONITOR
REC
PLAY
SET
4
JB-2MED
TALK
CALL
MONITOR
REC
PLAY
SET
JB-2MED
TALK
CALL
MONITOR
REC
PLAY
SET
JB-2MEDJB-2MD
JB-2MEDJB-2MD
CALL
MONITOR
CALL
MONITOR
SETPLAYREC
Transfer entrance call
English
1. Press the CALL button during communication with an
entrance station.
2. An image of the entrance is displayed on all of the monitor
stations.
3. If the transferred station presses the TALK button, room-
to-room communication starts.
4. If the transferred station presses the TALK button again, it
switches to entrance station calling mode. By pressing the
TALK button once more, communication is established
with the entrance station. To end, press and release the
TALK button.
NOTES: 1. The call-in from the entrance station will be held
for 45 seconds. End the room-to-room
communication within this timeframe.
2. Communication ends automatically after
approx. 1 min.
7-8
01/APR/04 15:30
16-picture, 4-frame mode 16/32/60-picture mode
6 sec.2 sec.
14 sec.10 sec.
2 sec.
01/APR/04 15:30
JB-2MED
SET PLAY REC
Automatic recording
English
If a call is received from the entrance, the unit starts
recording automatically. The REC button lights during
recording.
• 16-picture/4-frame mode: Records at approx. 2 sec., 6 sec.,
10 sec. and 14 sec. from time of call-in.
• 16/32/60-picture mode: Records after approx. 2 sec.
NOTES: 1. The automatic recording function cannot be
cancelled.
2. The screen shown when monitoring the
entrance is not recorded automatically. If you
wish to record this screen, press REC button.
3. When automatic recording has finished, for
approx. 15 sec. after the monitor screen goes
off, automatic recording will not be activated for
the same entrance station even if a call is placed
(to prevent prank calls).
7-9
JB-2MED
TALK
CALL
MONITOR
REC
PLAY
SET
JB-2MED
TALK
CALL
MONITOR
REC
PLAY
SET
JB-2MED
Manual recording
English
1. Display a video image with the entrance MONITOR button.
2. Press the REC button. The REC button lights and
recording starts.
NOTES: 1. Even if 16-picture/4-frame mode is selected,
only 1 frame is recorded in manual mode.
2. If manual recording is activated when a call is
received from an entrance station, it overwrites
the automatically recorded image.