Aiphone GFO-1DL Intercom System User Manual


 
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device , pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try and correct the interference by one or more of the following measures:
— Reorient or locate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
FCC Class B Verification
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Pg. 5
GFO-1DL(F) Instr.
1105PHJS
Toll Free Technical Support:
1-800-692-0200
Email: tech-serv@aiphone.com
NOTE:
Only information pertaining to the GFO-1DL is included here. For complete installation, wiring, programming and operational
information, please refer to the GF Installation Manual, GF-MK and GF-NS/A manuals.
SPECIFICATIONS:
System Capacity: Max. 100 units in a system with all GFO-1DL's. Each GFO-1DL takes the capacity of 2.5
standard GF-1DK handset models.. If intermixing, multiply each GFO-1DL in the system
(including 2nd tenant stations also) by 2.5, then add the number of handsets included. Total
number must not exceed 250.
Communication: Push-to-talk, release-to-listen at tenant station. Press END to conclude call (like hanging up
handset)
Hands free from entrance panel to tenant
Calling: Electronic ring tone from entrance panel to tenant station
Differentiated ring tone from individual doorbell
Wiring: 2-conductor common bus wire throughout system. Max. 20 units on each trunk line.
Run additional independent 2-cond. wire from each unit’s doorbell button to unit (if included),
and 2 cond. from GFK-PS panic switch to GFO-1DL.
Wiring Distance: GF-BC to farthest GFO-1DL: 980' with 20AWG
Total cumulative wire distance must not exceed 1.5 miles (8,200') with 20AWG
Wire: Use Aiphone wire # 872002. Additional year warranty on the system with Aiphone wire.
Dimensions: 7-1/8” H x 5-5/8” W x 2-1/8” D (GFO-1DL)
8-1/8" H x 6-1/8" W x 1-3/8" D (GFO-1DLF)