3Com 3CR17450-91 Two-Way Radio User Manual


 
The Power-up Sequence 25
The Power-up
Sequence
The following sections describe how to get your Switch 3870
powered-up and ready for operation.
Powering-up the
Switch 3870
Use the following sequence of steps to power-up the Switch.
1 Plug the power cord into the power socket at the rear of the Switch.
2 Plug the other end of the power cord into your power outlet.
The Switch powers-up and runs through its Power On Self Test (POST),
which takes approximately 1 minute.
Checking for Correct
Operation of LEDs
During the Power On Self Test, all ports on the Switch are disabled and
the LEDs light in a rapid sequence.
When the POST has completed, check the Unit Status to make sure that
your Switch is operating correctly. Table 7
shows possible colors for the
LED.
Table 7 Unit Status Colors
If there is evidence of a problem, see “Solving Problems Indicated by
LEDs” on page 48 for a list of suggested solutions.
CAUTION: The Switch has no ON/OFF switch; the only method of
connecting or disconnecting mains power is by connecting or
disconnecting the power cord.
Connecting a
Redundant Power
Supply
You can connect a SuperStack 3 Advance Redundant Power System to
the Switch. This unit, which is also known as RPS, is designed to maintain
the power to your Switch if a power supply failure occurs.
For normal redundancy, the unit requires a Type 3 Power Module (part
number 3C16075)
Color State
Green The Switch is powered-up and operating normally.
Yellow The Switch has failed its Power On Self Test (POST).
Off The Switch is not receiving power.
DUA1745-0AAA02.book Page 25 Monday, August 9, 2004 11:51 AM