5 - 150
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
5.7.2 Axis control data
Setting item Setting details
Cd.3
Positioning start No.
Set the positioning start No.
(Only 1 to 600 for the Pre-reading start function. For details, refer to Section
12.7.8 "Pre-reading start function".)
Cd.4
Positioning starting point No.
Set a "starting point No." (1 to 50) if block start data is used for positioning.
(Handled as "1" if the value of other than 1 to 50 is set.)
Cd.5
Axis error reset
Clears the axis error detection, axis error No., axis warning detection and axis
warning No.
When the QD75MH axis operation state is "in error occurrence", the error is
cleared and the QD75MH is returned to the "waiting" state.
Cd.6
Restart command
When positioning is stopped for any reason (when axis operation state is
"stopped"), set "1" in
Cd.6
. Positioning will be carried out again from the stopped
position to the end point of the stopped positioning data.
Cd.7
M code OFF request
The M code ON signal turns OFF.