5 - 142
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Storage item Storage details
Md.48 Deceleration start flag
"1" is stored when the constant speed status or acceleration status switches to
the deceleration status during position control whose operation pattern is
"Positioning complete".
"0" is stored at the next operation start or manual pulse generator operation
enable.
POINT
This parameter is possible to monitor when "
Cd.41
Deceleration start flag valid
" is valid.
Md.100
OPR re-travel value
This area stores the travel distance during the OPR travel to the zero point that
was executed last time.
For setting units
Update timing: 1.7ms
Example) mm
(Buffer memory
0.1) µm
Md.101
Real current value
This area stores the present value (feed present value – deviation counter droop
pulses).
Update timing: 1.7ms
Example) mm
(Buffer memory
0.1) µm
Md.102
Deviation counter value
This area stores the difference between the feed present and the actual present
value.
(Buffer memory details) PLS
Update timing: 1.7ms
Md.103
Motor rotation speed
This area stores the present rotation speed of the servomotor.
(Buffer memory
0.1) rpm
Update timing: 1.7ms
Md.104
Motor current value
This area stores the present motor current value of the motor.
(Buffer memory 0.1) %
Update timing: 1.7ms