Teledex CL2100 Cordless Telephone User Manual


 
PREPARING TO USE THE CL2100 SERIES TELEPHONE
BASE PREPARATION PROCEDURE
1) Insert either end of the RJ-45 cable into the jack on the back of the telephone labeled
“LINE.”
2) Insert the other end of the cable into the jack on the AC adapter labeled “PHONE.”
Note:
The base may emit a “beep” tone when the power is switched on.
3) Insert one end of the RJ-11 line cord into the jack on the AC adapter labeled “LINE.”
4) Insert the other end of this line cord into a telephone wall outlet jack.
5) Plug the AC adapter into an available, unswitched electrical wall outlet.
6) Remove the plastic overlay and place the paper faceplate over the keys. Replace the
plastic overlay by hooking the tabs on the overlay into the recessed slots located on
both sides.
Hint
: The overlay is easiest to insert when the left or right side tabs are inserted first,
and the middle of the overlay is slightly bowed to allow for insertion of the other tabs.
7) Place the cordless handset on the base unit.
Note:
The speakerphone may turn on and speakerphone LED illuminate when the
base unit is first powered on. Press the Speakerphone “On/Off” button to reset the
speakerphone to the off position.
HANDSET PREPARATION PROCEDURE
1) Prepare to install the battery into the handset by first removing the rubber screw cover
and the screw beneath. Then firmly press down on the top of the battery compartment
cover and slide it towards the bottom of the handset until it is removed.
2) Insert the battery connector into the connector inside the handset.
3) Replace the battery compartment cover, retaining screw and rubber screw cover.
Note:
The handset may emit a “beep” tone when the battery is connected. The “ON”
key will blink to indicate the handset is searching for the base. It will stop blinking
when the handset is registered to base. This is an indication that the telephone is ready
to be used. To ensure optimal performance of the telephone charge the battery overnight.
See charging details under “Charging the Battery.”
BASE – HANDSET REGISTRATION PROCEDURE (FOR HOTEL TECHNICAL SERVICE PERSONNEL ONLY)
To register the CL2100 series handset to the base:
1) Press and hold the “CONF” key until a running light appears on the handset “Line 1,”
“Line 2” and “CONF” LED’s.
2) Press the numbers 4, 5 and 6 (in sequence) on the keypad. The “Line 1,” “Line 2” and
“CONF” LED’s will be flashing. Immediately press and hold both the “PAGE” key
and the “HOLD” key on the base simultaneously, until two continuous beeps are
heard from the base unit. When a link between the base and handset is established,
the “Line 1” and “Line” 2 LED’s on handset will be in a steady “on” state. When
both LED’s turn off, the registration procedure is completed.
3) To confirm the handset is successfully registered to the base, press the “PAGE” key on
the base. The handset will beep for a short period. The handset will stop beeping if it
is answered, by pressing the “Line1” or “Line 2” keys on the handset, or by pressing
the “PAGE” key on the base again.
CHARGING THE BATTERY
The rechargeable Nickel Metal Hydride battery must be fully charged before using the
phone for the first time. It is recommended that the battery pack be charged overnight
1
Charge LED
100 ms
300 ms
600 ms
Store Key
Programmimg Port
Auto Dial Keys
M1 - M5
(model CL2105)
M1 - M10 (model CL2110)
DTMF Keys
Volume Keys
Paging Key
Message Waiting Lamp
Flash
Programming
Keys
Hold
Redial
Line 2
Line 1 Conference
Mute
Speakerphone
Hold
Key
Line
On/Off
Keys
Conf.
Redial
Volume
Keys
Flash
CL2100 SERIES TELEPHONE DIAGRAM
EC DECLARATION OF CONFORMITY
This product has been certified by an independent, accredited test house that it complies with the
requirements of the following directives:
European Community Directive 73/23/EEC and 93/68/EEC, based on the standards:
EN 60950:1992+A1+A2+A3+A4+A11 / EN 41003:1998
Test report Nr.: G0M20106-4905-L Dated: June 19, 2001
R&TTE Directive 1999/5/EC on the approximation of the laws of the member states
relating to network connection and radio spectrum matters, based on the following
standards: I-CTR 37 (1998) TBR 10 (1997) TBR 6 (1997)
R&TTE Directive 1999/5/EC and Council Directive 89/336/EEC on the approximation
of the laws of the member states relating to electromagnetic compatibility, based on the
following standards: EN 301 489-1/-6, EN 50081-1, EN 50082-1
CONTACTING TELEDEX
Telephone: 01.408.363.3100
Internet: www.teledex.com
email: sales@teledex.com
part number 600-0480-48A
Address: 6311 San Ignacio Avenue
San Jose, CA 95119
USA
CONGRATULATIONS AND THANK YOU
Congratulations on your purchase of this high-quality, Teledex-made European ETSI DECT-based
hospitality guestroom cordless telephone. Teledex LLC is the world's leading hospitality telephone
supplier, with over five million phones shipped worldwide. If you have any questions about this
telephone, please feel free to contact us via one of the methods below. We appreciate your purchase!