You can set the microphone sensitivity of the baby unit to the desired level. You can only change the
microphone sensitivity when a connection between the baby unit and the parent unit has been
established, i.e. when the LINK light on the parent unit lights up green continuously.
1 Select ‘Sensitivity’ with the + and - buttons.
2 Press the OK button to conrm.
3 Select the desired microphone sensitivity level for the baby unit with the + and - buttons.
k = minimum sensitivity level
l = maximum sensitivity level
4 Press the OK button to conrm.
The message ‘Saved’ appears on the display.
Note: When the microphone sensitivity of the baby unit is set to a high level, it picks up more sounds and
therefore transmits more often. As a result, the units consume more power.
Sound alert on/off
Note: You can only switch the sound alert on and off in the menu of the parent unit.
This feature allows you to monitor your baby silently. It enables you to switch off the volume on
your parent unit and still be alerted if your baby cries.
If the sound alert is switched on, the parent unit beeps as soon as the fourth sound level light lights
up blue while the volume is switched off. In addition, the backlight of the parent unit display goes on
and the sound alert symbol (R) ashes on the display.
1 Select ‘Sound Alert’ with the + and - buttons.
2 Press the OK button to conrm.
3 If the alert is off, the display shows ‘On?’. Press the OK button to switch on the alert. If the
alert is on, the display shows ‘Off?’. Press the OK button to switch off the alert.
If you have set the sound alert to ‘on’, the sound alert symbol ( R) appears on the display of
the parent unit.
Setting room temperature range
Note: You can only adjust the temperature range in the menu of the parent unit.
A baby will sleep comfortably in a room heated to a temperature between 16°C and 20°C. This is
important, since a baby cannot regulate its body temperature as well as an adult. A baby needs
more time to adjust to temperature changes.
If you do not set a temperature range, the baby monitor alerts you when the temperature in your
baby’s room drops below 14°C or rises above 30°C. In this case, the backlight of the parent unit
display goes on and ‘High’ or ‘Low’ appears on the display. To change the default minimum and
maximum temperature, follow the instructions below.
Note: The temperature of the baby’s room is shown on the display of the parent unit when they are
linked.
1 Select ‘Temperature’ with the + and - buttons.
2 Press the OK button to conrm.
3 Select ‘Range’ with the + and - buttons.
4 Press the OK button to conrm.
5 Set the desired minimum temperature with the + and - buttons.
6 Press the OK button to conrm.
7 Set the desired maximum temperature with the + and - buttons.
,
,
,
,
ENGLISH 13