NEC 1093092 Cordless Telephone User Manual


 
Installation
Installing the Base
4
Chapter 1: Installation
DSX Cordless Lite II Telephone User Guide
Installation
Installing the Base
Connecting the Base
To connect the base to the DSX system
(Figure 2: Installing the Base)
:
1. Install a modular jack within 6 feet of the base and within 6 feet of an available standard (NEMA 5-15R)
120 VAC outlet.
2. Run a single pair of 24 AWG station cable from an available
16ESIU PCB digital station port
on a sta-
tion block to the modular jack.
3. Terminate the station cable
WHT/BLU - BLU/WHT
leads to the
RED
and
GRN
lugs on the modular jack.
4. Plug one end of a modular line cord into the base
LINE IN
jack; plug the other end of the line cord into
the modular jack.
5. (Optional) Plug an accompanying DSX keyset into the
LINE OUT
jack in the base.
- While the keyset and the cordless handset are idle, you can press
Cordless
and
Desk
on the base
to activate either phone (and deactivate the other).
To connect the AC Adaptor to the base:
1. Run the AC adaptor cord under the strain relief on the back of the base as shown.
2. Plug the AC adaptor into AC outlet.
3. Be sure the base antenna is in the vertical position.
Checking the Base LEDs
Normal Operation when the cordless handset is operational
When the cordless handset is operational, the
Power
and
Cordless
LEDs are on.
When the keyset is operational, the
Power
and
Desk
LEDs are on.
Troubleshooting
If the
Power
LED is off, the base power supply is not properly connected.
Be sure to review
Guidelines for Placing the Base,
Figure 3: Correct Installation Methods, and Figure 4:
Incorrect Installation Methods prior to connecting the base unit to the system.
Guidelines for Placing the Base
1. For best results, the base unit should be placed in line-of-site with its handset.
2. Cordless telephone range and reception can vary from site to site. Some of the things that may
adversely affect range and reception are:
Placing the base against or close to a wall (particularly if the wall has metal studs).
Positioning the base close to a device that emits Electromagnetic Interference (EMI), such as a TV,
radio, computer, uorescent light, fax machine, or printer.
Installing the base close to other 900 Mhz devices, such as Symbol or Telex hand-held inventory
devices.
Installing the base above a ceiling that uses foil-backed insulation.
Installing the base behind a door which can be closed, tinted windows, or one-way glass which will
separate the base from the handset.
3. Always raise the base unit antenna to its full vertical position.
4. When installing more than one cordless in the same site:
Be sure the base units are at least 15 feet apart.
5. After installation, change each telephone’s channel by pressing CH on the handset. This will minimize
interference between your cordless telephones.