13-4940-00251 Commend SIP Doorphone
Commend doorphone Configuration Notes
The following steps show how to program the Commend doorphone to interconnect with the
3300ICP.
The configuration settings below are the main reference points and by any means could not be
considered as the comprehensive configuration instructions.
We strongly recommend contacting the phones’ manufacturer Commend International GmbH
website http://www.commend.com/sip for more detailed instructions and manuals.
Accessing Commend Doorphone
In our test environment, we configured Commend doorphone through the web interface.
The SIP stations are delivered ex works with a standard IP address, via which the web interface
of the station can be accessed:
IP address 192.168.1.200
Subnet mask 255.255.255.0
If the station can not be used in the local network (LAN) with this IP address, then the following
procedure is recommended:
Establish connection between PC and SIP station via a hub (or switch) or via a direct
connection cable.
The PC must be in the same subnet as the SIP station.
This means, an appropriate IP address of that subnet range (e.g. 192.168.1.199) has to be
allocated to the PC temporarily.
Note: When connecting the SIP station with this IP-address to the local network (LAN), it is
essential to make sure that this IP-address does not already exist in the network! Take a note of
IP address assigned to the phone, e.g. 192.168.101.131.
After entering the IP address, a login dialogue appears where following data has to be entered:
User name factory default: admin
Password factory default: commend