Marmitek FD10 Telephone Accessories User Manual


 
8 © MARMITEK
Do the FD10 units need to be attached to the phase circuit?
Not necessarily. If you only want to couple and not filter, the FD10 units can also be attached
to the phases via a parallel connection. This makes the installation a lot simpler.
After placing the FD10 units, my installation does not work as well as before. What
went wrong?
The FD10 units were not connected properly. The ingoing and outgoing phases were switched
round, which means the FD10 suppresses the signals on the installation in your house.
What is the difference between 3 FD10s and the CAT3000?
When using 3 FD10s, the signals are spread over different phases (the phases are coupled). The
CAT3000 couples the phases and also amplifies the signal (repeater) and also couples the extra
MicroModules signals.
What tricks and tips can I use to enhance the reach of the X-10 signals?
See http://www.marmitek.com/en/klantenservice/marm_x10_tips.html for more information.
Do you still have questions? Please check out www.marmitek.com for more information.
techNical speciFicatioNs
Supply voltage: 230VAC, 50 Hz
Maximal current: 63 A
Central filter frequency: 120 kHz
Bandwidth filter: 5 kHz min. (3 dB points)
Attenuation incoming: 20 dB min. for I = 0 A
15 dB min. for I = 63 A
Attenuation outgoing: 15 dB min.
Input impedance: 20 Ohm min. for f = 120 kHz
Coupling loss: 2 dB max. for f = 120 kHz
Connectors: Screw connectors for phase (supply), phase (premises),
null and connection.
Surrounding temperature: -10°C to +50°C (business premises)
-20°C to +70°C (warehouse)
Measurements: 35x80x65 mm