8 Local Programming Functions
Function 01: Change Master Password
The master password is used to protect the database that was entered
via local programming. The master password can be changed using
this function.
Default password “123456” still should be used (instead of the changed
Master Password) when AB2000 or AXNET connection is used to
connect to the controller.
Function 02: Directory Code Length
(AE1000Plus and AE2000Plus Only)
The factory settings sets the Directory Code Length at 3 digits. The
length of the Directory Code can be changed from 2 to 4 digits using
this function.
Function 05: Date & Time
Using this function, the date and time can be entered. It should be the
Controller’s current local date and time regardless if Daylight Saving
Time is currently being observed at the Controller’s location.
At the prompt of the DST fi eld, the Controller will display “ENABLED” on
the second line if the previous DST setting is enabled; and “DISABLED”
if the previous setting is disabled.
Enter a “1” to enable DST or a “0” to disable DST if the setting is to be
changed. If the DST value will not be changed, enter # to accept the
displayed value.
If the Controller will observe DST, then regardless whether the current
local time is in DST or not, the DST fi eld should always be entered as
a “1”. For example, suppose that current date is January 20, 2008 and
local time is 10:00 AM and the Controller will observe DST, even though
the current time is not in DST, the installer should enter January 20,
2008 as the date, 10:00 as the time and 1 for DST fi eld.
The panel will have a default value of “DST Enabled” when Local
Programming mode is fi rst enabled.
Function 06: Time Zones
Two time zones utilizing two time periods each are programmable with
this function. Holidays are not included.
The entry of the fi rst period is required. The entry for the second period
of the time zone is optional. To skip it, enter a “#” key at the prompt for
the second period to end the Time Zone function code entry.
When entering days of the week, enter all the active days.
Monday =1
Tuesday = 2
Wednesday = 3
Thursday = 4
Friday = 5
Saturday = 6
Sunday = 7
FCN 01
01#PW#PW#
PW = NEW 6-DIGIT PASSWORD
CHANGE MASTER PASSWORD
FACTORY SETTING: 123456
FCN 02
02#LENGTH#
LENGTH = 2 TO 4 DIGITS
SET DIRECTORY CODE LENGTH
FACTORY SETTING: 3 DIGITS
FCN 05
YEAR = 2000 - 2127
MONTH = 1 - 12
DAY = 1 - 31
SET DATE AND TIME
05#YEAR#MONTH#DAY#HOUR#MINUTE#DST#
HOUR = 0 - 23 (LOCAL TIME)
MINUTE = 0 - 59
DST = 1 FOR ENA; 0 FOR DIS
FCN 06
TZ NUM = TIME ZONE NUMBER 1 OR 2
ACT DAY = ENTER ALL ACTIVE DAYS MON-SUN = 1-7
ST HR1 = START HOUR #1, ENTER 0-23
ST MN1 = START MINUTE #1, ENTER 0-59
EN HR1 = END HOUR #1, ENTER 0-23
EN MN1 = END MINUTE #1, ENTER 0-59
ST HR2 = START HOUR #2, ENTER 0-23
ST MN2 = START MINUTE #2, ENTER 0-59
EN HR2 = END HOUR #2, ENTER 0-23
EN MN2 = END MINUTE #2, ENTER 0-59
SET TIME ZONES
06#TZ NUM#ACT DAY#
ST HR1#ST MN1#EN HR1#EN MN1#
ST HR2#ST MN2#EN HR2#EN MN2#