Monitor (CLR) Switch Operation In Scan
The CLR switch does not operate while scanning inactive channels. When
a channel becomes active, the CLR switch operates only during the scan hang
time after the channel activity disappears.
Channel Changes In Scan
Pushing the channel switches (UP or DOWN) while scan is turned on will
change the SELECTED channel assignment. If a signal is being received and
the channel switches are pushed, the radio will revert to the new SELECTED
channel assignment. After 2 seconds, if no activity appears on the new
SELECTED channel, scanning will resume. If the SELECTED channel is
changed to a channel not in the scan list, the new channel will be temporarily
added to the scan list until the SELECTED channel is changed again.
Temporary channel deletions
The SCAN function must be turned off to make any permanent changes
(additions, deletions, re-priorizations) to the scan list. While in scan,
temporary channel deletions may be made to the scan list. The original
scan list will be back in effect by either turning scan off (by pushing the
SCAN switch ) or by turning the radio power off and back on.
When the radio stops scanning on an active channel, the channel may
be temporarily deleted by holding the SCAN switch and then pressing
the CHANNEL/SEL () switch. The radio will immediately resume
scanning while skipping over the temporarily deleted channel.
Temporary deletions cannot be made until the radio stops on an active
channel. P1 and P2 channels cannot be temporarily deleted.