INSTALLATION & MOUNTING
Installation Instructions:
1. If the IPW-1A adaptor is not on the same LAN or
network segment as the PC master station, ensure
that the IPW-1A has been pre-programmed with the
proper connection settings prior to physical adaptor
installation. See the CommuniCenter Operations
manual (included on CD with IPW-1A).
2. Wire the sub station to the proper connector on the
IPW-1A, and connect to the network using the
standard RJ-45 jack. Wiring from the sub station to
the IPW-1A should be a 2-conductor, shielded cable.
Connect the PT-1211C power supply included to the
power input connector.
Mounting Instructions:
1. Mount the IPW-1A adaptor in a controlled area or in an enclosure suitable to
the installation environment. The IPW-1A chassis is neither vandal resistant
nor weather resistant. Secure the provided mounting bracket and then slide
the IPW-1A onto the bracket as shown. If mounting the unit on a shelf, attach
the 4 rubber feet that are included.
Pg. 2
Wiring to sub station should be 2-conductor shielded cable.
Wire distance from IPW-1A to IE series sub station:
22AWG = 387 feet, 18AWG = 980 feet
RESET RS-232 STATUS
SUB
PT-1211C
SUB
1
2
Audio Only Door
IE Series sub station
IN0 IN1 NC C NO
LAN
PWR
POWER
PT
Note:
Contact rated at 30V, 1A.
1. Load the software onto the PC to be used as a master station. Insert the CD (included with IPW-1A) or download the
latest version from the Aiphone website (www.aiphone.com).
2. Install the CommuniCenter software by following the on-screen prompts, or by executing “setup.exe” to begin the
installation process.
3. Consult the CommuniCenter Operation manual document for further software functionality and configuration
information.
NOTE – If installing system over a WAN please refer to the CommuniCenter Operation manual.
CommuniCenter SOFTWARE INSTALLATION
4-11/16"
4"
1-5/8"
*