INSTALLATION (continued)
6
INSTALLING THE GAS GRIDDLE
Refer to the nameplate. Verify the fuel type and pressure, which must
match the nameplate specifications. Connecting the hotplate to the
wrong fuel type and/or pressure will compromise the safety and/or
performance of the appliance.
BE SURE TO MAINTAIN REQUIRED CLEARANCES TO
COMBUSTIBLE SURFACES.
The appliance must be placed in its final operational position and
leveled front-to-back and side-to-side, with a spirit level, prior to
beginning the gas piping installation. Re-check the level of the unit
at the conclusion of the gas piping installation.
Each gas appliance is supplied with a separate gas pressure
regulator, which must be installed on the manifold pipe protruding
from the rear of the griddle. Ensure that the regulator is installed
such that the flow arrow stamped on the body of the regulator points
toward the griddle. Failure to properly install the supplied regulator
will result in an extremely hazardous condition.
A moisture trap (drip leg) consisting of a tee, 4” nipple pointing down,
and cap must be installed upstream of the gas pressure regulator.
A manual gas shut-off valve may be required by local codes and is,
in any case, strongly recommended. The shut-off valve must be
installed between the gas supply piping and the gas pressure
regulator.
It is the responsibility of the gas piping installer to identify the code
requirement for a shut-off valve.
Shut-off valves, moisture trap and all associated piping must be
supplied by the gas piping installer.
DANGER:
FIRE AND
EXPLOSION
HAZARD
NEVER use an open flame to
check for gas leaks. Fire and
explosion may result.
IMPORTANT:
All pipe joints must be checked
for leaks before lighting. Leak
checks should be performed
with a soap and water solution.
WARNING:
FIRE HAZARD
This appliance is supplied with
a gas pressure regulator.
Failure to properly install the
supplied regulator will result in
an extremely hazardous
condition.
Flow arrow stamped on body
of regulator must point toward
the griddle.
Vent hole must point UP.
IMPORTANT:
Verify fuel gas type. If the
available fuel does not match
the nameplate specification,
exchange the appliance for the
correct type.
IMPORTANT:
The appliance and its
individual manual shutoff valve
must be disconnected from
supply system piping during
any pressure testing of that
system at pressures in excess
of 1/2 p.s.i. (3.5 kPa).
Also, the appliance must be
isolated from the gas supply
piping system by closing its
individual manual shutoff valve
during any pressure testing of
the gas supply piping at test
pressures equal to or less than
1/2 p.s.i. (3.5 kPa).
Fig. 2 Gas Supply Piping
FLOW
DRIP LEG*
GAS
SHUT-OFF
VALVE*
SUPPLIED
REGULATOR
* by others
BACK OF BROILER
GAS
SUPPLY*
VENT
164 307737 OpManual for HDCR-Series Char-Rock Broilers