4.1.2.2 Black Sensor:
Press the button under and icon to select the sensor calibration
mode, and press the under “]” icon to start sensor calibration.
4.1.2.2.1 Auto Bline:
When enter the [Auto Bline] option, you will see following message.
Normally, we use Auto Bline to calibrate sensor sensitivity.
Insert label on the black mark sensors, and press the button under “V” icon
to start sensor calibration.
Note:
DO NOT align black mark to the black mark sensor when
calibrate black mark sensor or sensor will be calibrated
incorrectly.
Press the button under “+” and “-“ icon to increase and decrease
Stock AD value, and press the under “V” icon to calibrate sensor.
When sensor is calibrated successfully, press the button under
“” icon to return to the previous page.
If “FAILED” is shown on the LCD display, please check if only paper
Auto Bline
Manual Bline
]
Insert label ...
Then hit Enter
V
Bline Calibrate
150
+ - V
Calibrating ...
Stock AD = 256
SUCCESSFUL
Stock AD = 150