![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/e3/de365ad2-59f6-4204-bf32-4f6b8d97ce3d/de365ad2-59f6-4204-bf32-4f6b8d97ce3d-bg61.png)
6
UTILITY PACKAGE (GX Configurator-CT)
6.1 Utility Package Functions
6 - 2
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
PROCEDURES AND
SETTINGS BEFORE
OPERATION
5
FUNCTIONS
6
UTILITY PACKAGE (GX
Configurator-CT)
7
PROGRAMMING
8
TROUBLESHOOTING
Monitor/Test
(1) Monitors/tests the following buffer memories and I/O signals of the QD64D2.
• Y device
• CH Ring counter lower limit
• CH Ring counter upper limit
• CH Preset value setting
• CH Coincidence output No.1 point setting
• CH Coincidence output No.2 point setting
• CH Coincidence output No.1 point change request
• CH Coincidence output No.2 point change request
• CH Continuous comparison No.1 start point setting
• CH Continuous comparison No.1 repeat point setting
• CH Continuous comparison No.1 ON time setting
• CH Continuous comparison No.1 point n setting (n: 1 to 16)
• CH Continuous comparison No.2 start point setting
• CH Continuous comparison No.2 repeat point setting
• CH Continuous comparison No.2 ON time setting
• CH Continuous comparison No.2 point n setting (n: 1 to 16)
(2) Monitors the following buffer memories of the QD64D2.
• X device
• CH Present value
• CH Latch count value
• CH Overflow detection flag
• CH External I/O status monitor
• CH Error code
• CH Warning code
• CH Continuous comparison No.1 point monitor during comparison
• CH Continuous comparison No.2 point monitor during comparison
Section 6.6
Table 6.1 Utility package (GX Configurator-CT) functions list
Function Description Reference