A SERVICE OF

logo

- 5 -
COMMAND PARAMETER function example
CV SB UP ---SURROUND BACKch (SBch 1SP) CVSB UP<CR>
SB DOWN CVSB DOWN<CR>
SB ** **:38 to 62 by ASCII , 50=0dB CVSB 50<CR>
MU ON OUTPUT MUTE ON/OFF change MUON<CR>
OFF MUOFF<CR>
SI PHONO Select INPUT source SIPHONO<CR>
CD SICD<CR>
TUNER SITUNER<CR>
DVD SIDVD<CR>
VDP SIVDP<CR>
TV SITV<CR>
DBS/SAT SIDBS/SAT<CR>
VCR-1 SIVCR-1<CR>
VCR-2 SIVCR-2<CR>
VCR-3 SIVCR-3<CR>
V.AUX SIV.AUX<CR>
CDR/TAPE1 ---Select CDR/TAPE function at AVR-4802R SICDR/TAPE1<CR>
MD/TAPE2 ---Invalid at AVR-4802R SIMD/TAPE2<CR>
ZM ON MAIN-ZONE ON/OFF change ZMON<CR>
OFF ZMOFF<CR>
Z1 PHONO MULTI ZONE -1 mode set , and select source Z1PHONO<CR>
| ---The name of PARAMETER is |
MD/TAPE2 the same as that of the time of SI COMMAND. Z1MD/TAPE2<CR>
SOURCE MULTI ZONE -1 mode cancel Z1SOURCE<CR>
UP MULTI ZONE -1 VOLUME UP/DOWN , direct change to ***dB Z1UP<CR>
DOWN Z1DOWN<CR>
** **:00 to 99 by ASCII , 80=0dB, 99=---(MIN) Z180<CR>
ON MULTI ZONE -1 ON/OFF change Z1ON<CR>
OFF Z1OFF<CR>
---Set MULTI ZONE functions at AVR-4802R