Equipment Installation Manual,
GEN-X Electronic Flight Bag
1069-2510-01 D.doc
1069-2510-01
Rev D
Page 18 of 27
ENVIRONMENTAL:
The GEN-X meets the environmental test categories detailed below in accordance with RTCA/DO-160E,
Environmental Conditions and Test Procedures for Airborne Equipment
and 14 CFR 25.869 Code of
Federal Regulations: Title 14 Aeronautics and Space; Subpart D – Design and Construction; Subsection
25.869 (a)(4) – Fire Protection Systems.
NOMENCLATURE: GEN-X Electronic Flight Bag
PART NO: 1069-4000-01, 1069-4808-XX and 1069-4700-XX
MANUFACTURER: DAC International
ADDRESS: 6702 McNeil Drive, Austin, TX 78729
Standard/Section Category Remarks
DO-160E
4.0 Temperature and Altitude
A4
Temperature: Category A4,
Operating Low temp; -15ºC and
Operating High temp; +55ºC, Short
time Operating Low temp; -30ºC and
Short time Operating High temp;
+55ºC, Ground Survival Low temp;
-55ºC and Ground Survival High
Temp; +85ºC.
Altitude: Category
A1, Altitude at 50,000 feet for 2
hours, Decompression from 8,000
feet to 50,000 feet within 15 sec.,
Overpressure at -15,000 feet for
10 minutes.
5.0 Temperature Variation
B
5° C per minute
6.0 Humidity
X
Not tested
7.0 Operational Shock and Crash Safety
B Saw-tooth 6g, 11msec, 3 shocks
per direction. Saw-tooth 20g
11msec, 3 shocks per direction.
8.0 Vibration
X
Not tested
9.0 Explosion Proofness
X
Not tested
10.0 Waterproofness
X
Not tested
11.0 Fluids Susceptibility
X
Not tested
12.0 Sand and Dust
X
Not tested
13.0 Fungus Resistance
X
Not tested
14.0 Salt Spray
X
Not tested
15.0 Magnetic Effect
Z
Less than 0.3 meter
16.0 Power Input
X
Not tested
17.0 Voltage Spike
X
Not tested