INSTALLATION INSTRUCTIONS
Tools and Parts
Check that you have everything necessary for correct installation.
Proper installation is your responsibility.
Parts supplied:
Remove parts package from dryer drum. Check that all parts were
included.
4 leveling legs
Parts needed:
Check local codes. Check existing electrical supply and venting
and see “Electrical Requirements” and “Venting Requirements”
before purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your dryer. For further information, please reference the
“Assistance or Service” section of your “Dryer User Instructions.”
Location Requirements
You will need
A location that allows for proper exhaust installation. See
“Venting Requirements.”
A separate 30 amp circuit.
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) of
200 lbs (90.7 kg). The combined weight of a companion
appliance should also be considered.
A level floor with a maximum slope of 1 in. (2.5 cm) under
entire dryer. (If slope is greater than 1 in. [2.5 cm], install
Extended Dryer Feet Kit, Part No. 279810.) Clothes may not
tumble properly and models with automatic sensor cycles
may not operate correctly if dryer is not level.
Do not operate your dryer at temperatures below 45ºF (7ºC). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to open
fully.
Dryer Dimensions
*Most installations require a minimum 5½ in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Minimum installation spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Flat-blade screwdriver
Adjustable wrench that
opens to 1 in. (2.5 cm) or
hex-head socket wrench
(for adjusting dryer feet)
Level
#2 Phillips screwdriver
Vent clamps
Tin snips (new vent
installations)
Safety glasses
Caulking gun and
compound (for installing
new exhaust vent)
Gloves
Wire stripper (direct wire
installations)
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
1. Small Opening Side-Swing Door
2. Large Opening Side-Swing Door
3. Wide Opening Side-Swing Door
4. Wide Opening Hamper Door