Toshiba IP5000 Telephone User Manual


 
Hardware Connections
User Notes
Strata CIX IP5000-series Telephone UG 10/08 167
1.3. The Strata CIX system must be hardwired into a switched fused spur, (which
should comply with the requirements of a disconnecting device as specified in the
standard EN60950), the switch on the fused spur outlet shall be considered the AC
power disconnection device. This spur must be installed in accordance with 16th
edition of the IEE wiring regulations, aka BS7671:1992 or the latest edition of this
standard.
1.4. Environmental Installation details.
The Strata CIX is designed to work within the following environmental conditions:
-Operating temperature 0oC to 40oC
-Humidity 20% to 80%
2. EMC Compliance
Toshiba Information Systems (U.K.) Ltd declare that the Strata CIX40, 100, 200 &
670 complies with the EEC's EMC directive, Directive No. 89/366/EEC as amended
by directive 92/31/EEC. The product has been assessed and found to comply with the
following product specific standards:
·EN55022:1998-9, EN/IEC61000-3-2/1995, EN/IEC61000-3-3/1995
(Emissions)
·EN52024:1998, EN61000-4-2/1995+A1:1998, EN61000-4-3/1997+A1:1998,
EN61000-4-4/1995+A1:2001, EN61000-4-5/1995+A1:2001, EN61000-4-6/
1995+A1:2001, (Immunity)
The notes listed below form part of the products' compliance with the aforementioned
European Norm.
To ensure EMC compliance the system must installed in accordance with the
instructions in the "Installation and Maintenance" manual. In order to maintain
compliance any shielded cables supplied and/or ferrite suppression cores must be
used.