Paradyne 8965 Telephone Accessories User Manual


 
3. Configuration Using the Web Interface
3-8 June 2004 8900-A2-GB20-30
Configuring Alarm Threshold Profiles (8955, 8965, 8968)
Use the Configuration - Alarm Threshold Profiles screen to define sets of alarm
thresholds that you can apply to DSL ports.
To create an alarm threshold profile for a ReachDSL or ADSL line card:
1. Click on Create New Profile. The Alarm Threshold Profile Create screen
appears.
2. Enter or select the following fields:
Field Description
Profile Name Specify a name for this alarm profile.
Downstream / Near End Alarm Profile
Loss of Frame Seconds SNMP trap and TL1 autonomous message are sent if the
number of LOFS events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Loss of Power Seconds SNMP trap and TL1 autonomous messages are sent if
the number of LPRS events in a 15-minute interval meets
or exceeds the selected value (0–900 seconds, where 0
disables the messages).
Errored Seconds SNMP trap and TL1 autonomous message are sent if the
number of ES events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Severely-Errored Seconds SNMP trap and TL1 autonomous message are sent if the
number of SES events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Unavailable Seconds SNMP trap and TL1 autonomous message are sent if the
number of UAS events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Increasing Rate SNMP rate change trap and TL1 autonomous message
are sent if the current rate is greater than or equal to the
previous rate plus this threshold (0–65535 kbps, where 0
disables the messages).
Decreasing Rate SNMP rate change trap and TL1 autonomous message
are sent if the current rate is less than or equal to the
previous rate minus this threshold (065535 kbps, where 0
disables the messages).
Upstream / Far End Alarm Profile
Loss of Frame Seconds SNMP trap and TL1 autonomous message are sent if the
number of LOFS events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).